RealShock® HQF Series Lamp-Pumped Dual-Wavelength Long Pulse Laser
HQF series lamp-pumped dual-wavlength long pulse laser consists of a near-infrared laser module unit, a mid-infrared laser module unit and an energy detection module.This laser outputs dual wavelengths of 1064nm and 2940nm. Since different wavelengths target distinct chromophores and exhibit differential tissue penetration depths, they can be synergistically combined in clinical treatments. The system features high energy output, exceptional stability, and uniform beam distribution. Compatible accessories include output fibers, articulated arms, control panels, power supplies, and water-cooling units.
Product Parameters
Wavelength (nm) | 2940nm | 1064nm (300μm Fiber Coupled) | ||||||||
Nominal Pulse Width (μs) | 50 | 150 | 300 | 600 | 1000 | 150 | 300 | 750 | 15 ms | 25 ms |
Max. Repetition Rate (Hz) | 50 | 50 | 50 | 20 | 20 | 100 | 100 | 100 | 8 | 8 |
Pulse Energy (mJ@Max.Repetition Rate) |
120 | 120 | 50 | 40 | 120 | 50 | 50 | 50 | 1200 | 1200 |
Typical Repetition Rate (Hz) | 15 | 12 | 20 | 12 | 12 | 30 | 30 | 30 | 1 | 1 |
Max. Pulse Energy (mJ) | 450 | 700 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 2000 | 2000 |
Repetition Rate (Hz@Max. Pulse Energy) |
20 | 15 | 20 | 12 | 12 | 30 | 30 | 30 | 5 | 5 |
Max. Power (W) | 9 | 10.5 | 20 | 12 | 12 | 15 | 15 | 15 | 10 | 10 |
Other Optical & System Parameters | ||||||||||
2940nm&1064nm Beam Mode | Multi-mode | |||||||||
Output Method | Dual independent outputs: 2940 nm via articulated arm (appearance subject to end-user requirements); 1064 nm via optical fiber (200μm/300μm core) with automatic switching capability |
|||||||||
Laser energy stability (St) | ±20% max. | |||||||||
Laser energy reproducibility (Rp) | ±20% max. | |||||||||
Aiming Beam Wavelength | 532±20nm | |||||||||
Aiming Beam Power | >2mW, <5mW | |||||||||
Working Conditions | Ambient temperature: 10℃~30℃ | |||||||||
Relative humidity: 10%~73% (non-condensing) | ||||||||||
Atmospheric pressure: 86kPa~106kPa | ||||||||||
Power supply: AC220V, 50Hz, ≤10A |
1. All the data in the above table are the typical values obtained from the tests at room temperature of 25℃, and the final data is subject to the final test report.
Application
Periodontics
Implantology
Pigmentary Disorders
Vascular Lesions
Soft Tissue Surgery
Photobiomodulation
Key Features
Dual-wavelength output at 1064nm & 2940nm
Multiple operating modes
Excellent beam homogeneity
High stability
Compact architecture with hermetic sealing, high reliability